3
|
Components
Service manual
62
a
a Compressor pipe
CAUTION
Overheating the compressor pipes (and the oil inside the compressor pipes) will
damage or destroy the compressor.
9 After soldering is done, stop the nitrogen supply after the component has
cooled‑down.
10 Connect the Faston connectors to the compressor wire terminals U, V and W
U Wire terminal U
V Wire terminal V
W Wire terminal W
11 Install the cover of the compressor wire terminals.