To remove the switch box
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01E – 2023.01
a Compressor sound insulation
INFORMATION
This procedure is just an example and may differ on some details for your actual unit.
Prerequisite: Stop the unit operation via the user interface.
Prerequisite: Turn OFF the respective circuit breaker.
Prerequisite: Remove the required plate work, see
1 Remove the insulation on the upper side of the switch box.
a Insulation
b Main PCB
2 Disconnect all connectors from the main PCB.
3 Disconnect the electrical power supply wiring from the wire terminals.
b
a
3
Components
|
a
4
"3.9 Plate
work" [
 111].