Daikin FTXP20-71L Service Manual page 141

Table of Contents

Advertisement

To install the wifi control PCB wiring harness
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
Split Comfora R32
ESIE18-01E – 2023.01
4 Route the wiring harness out of the harness retainers and remove the wifi
control PCB wiring harness.
5 To install the wifi control PCB wiring harness, see
4
procedures" [
 139].
1 Connect the wiring harness connector to the indoor unit main PCB.
WARNING
When reconnecting a connector to the PCB, make sure to connect it on the correct
location and do NOT apply force, as this may damage the connector or connector
pins of the PCB.
2 Route the wiring harness through the appropriate harness retainers towards
the wifi control PCB.
3 Connect the wiring harness to the wifi control PCB.
4 Fix the wiring harness using new tie straps (if needed).
Is the problem solved?
Yes
No
3
Action
No further actions required.
Return to the troubleshooting of the
specific error and continue with the
next procedure.
Components
|
"3.14.2  Repair
Service manual