Daikin FTXP20-71L Service Manual page 60

Table of Contents

Advertisement

3
|
Components
Service manual
60
a
a Compressor pipe
8 Stop the nitrogen supply when the piping has cooled down.
INFORMATION
It is ALSO possible to cut the component pipe(s) using a pipe cutter. Make sure to
remove the remaining component pipe end(s) from the refrigerant pipes by heating
the brazing point(s) of the component pipe(s) using an oxygen acetylene torch.
9 Remove the nuts and bolts and remove the compressor from the unit.
a
c
a Nut
b Compressor
c Damper
10 Remove the 3 dampers from the compressor.
INFORMATION
The compressor dampers may look different.
11 Remove the bushings and keep them for re-use.
12 Install plugs or caps on the open pipe ends of the refrigerant piping to avoid
dirt or impurities from entering the piping.
13 To install the compressor, see
b
a
c
a
c
"3.2.2 Repair
procedures" [
ATXP20~35 + FTXP20~71 + ARXP20~35 + RXP20~71
a
4
 58].