Cleaning And Sanitizing Procedures; Daily: System Flush Procedure; Daily: Part Washing; Weekly: Sanitizing Procedure - Cornelius QUANTUM SERIES Installation And Service Manual

Corneilus installation & service manual beverage dispenser quantum series
Table of Contents

Advertisement

D
: S
F
AILY
YSTEM
LUSH
1. A 1 quart (0.95 liters) (32 fluid oz. minimum) empty container is needed. Place the empty con-
tainer on the drip tray grill under the nozzle of the dispensing station to be flushed.
2. Open the cabinet door.
3. Choose the valve handle that corresponds with dispensing station to be flushed.
4. Move chosen handle from "dispense" position to the "flush" position.
5. Close the door.
6. Depress and hold push button corresponding with dispensing station to be flushed, until clear
water is dispensed from the nozzle.
7. Move the handle to the "dispense" position.
8. Depress the push button for approximately 0.5 sec. and release. This will release water pres-
sure from the pump system.
It is recommended to use one or more quarts of water to flush a single dispensing station.
D
: P
W
AILY
ART
ASHING
1. Remove and wash dispensing nozzle, static mixer, splash plate, drip pan, bracket, and grille
in a mild detergent solution. Rinse thoroughly.
W
: S
EEKLY
ANITIZING
1. Remove juice concentrate container from unit and place in separate refrigerated compart-
ment.
2. Perform flush procedure.
3. Fill a clean empty concentrate container with one quart of extremely hot tap water, approxi-
mately 140°F (60°C) and place into unit. Run the hot water completely through unit into a large
container. When complete remove concentrate container.
4. Remove nozzles and static mixers from unit and rinse under hot tap water to remove excess
pulp.
5. Place nozzles and static mixers in separate container with 1 quart (0.95 liter) of sanitizing so-
lution and agitate vigorously, using brush (P/N 07932) to remove any excess pulp or concen-
trate (allow to soak for 2 minutes).
6. Clean bottle adaptor's inlet area along with dispensing platform tray with brush and sanitizing
solution to remove concentrate and pulp.
7. Clean valve mixing chambers with brush and sanitizing solution. (This is the cavity from which
the nozzle is removed).
8. Replace nozzles and static mixers into proper location.