Monthly Cleaning/Sanitation Procedures; Cleaning Conveyor Thru-Beam (Last Position) Sensor; Monthly Cleaning/Sanitation Of Ice Bin - Cornelius A.B.S. Unit Operator's Manual

Automated beverage system
Hide thumbs Also See for A.B.S. Unit:
Table of Contents

Advertisement

Cleaning Conveyor Thru-Beam (Last Position) Sensor

The thru-beam (Position "A") sensor requires cleaning. If not clean, the sensor may work
intermittently.
With the conveyor off, wet a clean napkin with carb water and carefully wipe the lens of the
thru-beam sensor emitter and the receiver.
(Note: Don't use cleaning towel on sensor, it may leave film on sensor lens.)

Monthly Cleaning/Sanitation of Ice Bin

WARNING: DO NOT USE SHARP OBJECTS, METAL DEVICES OR ABRASIVES ON THE ICE
HOPPER, TOP COVER, ICE CHUTE OR AGITATOR DISC AS IRREPARABLE DAMAGE MAY
RESULT. DO NOT USE SOLVENT OR OTHER CLEANING AGENTS AS THEY MAY ATTACK
THE PLASTIC MATERIAL.
Soapy Solution: Use a mixture of mild detergent and warm (100
Sanitizing Solution: Use 1/2 ounce of non-scented household bleach in one gallon of potable
water. Preparing the sanitizing solution at this ratio will create a solution of 200 PPM chlorine.
1. Turn ABS unit power switch OFF. The switch is located on the lower left-hand side of the ABS unit
front panel.
2. Remove top cover and set aside.
3. Remove all ice from the hopper and discard. If necessary, pour clean, potable water slowly into the
hopper to assist in melting the ice.
4. After all the ice is removed inspect the cold plate areas and drains as follows:
A. Remove the splash panel and the plastic cold plate access cover.
© 1999 The Coca-Cola Company, Cornelius and
McDonald's Corporation. All Rights Reserved.
Automated Beverage System

Monthly Cleaning/Sanitation Procedures

o
F) potable water.
44