Crushed Glass Installation - Travis Industries ProBuilder 54 Linear Installation Manual

Hide thumbs Also See for ProBuilder 54 Linear:
Table of Contents

Advertisement

Crushed Glass Installation

Do not allow the crushed glass to block the air slots or to become too thick (maximum 1
layer deep on the burner). Failure to properly install glass may lead to sooting and
improper burning.
If converting to LP (propane), convert the appliance prior to placing the crushed glass.
Install the crushed glass on the glass tray following the directions below.
1
Remove the setup pilot cover and the cover plate from the unit to access the pilot assembly underneath.
Remove the silicone sleeve that is shipped on the spark electrode. Re-install the cover plate and setup pilot
cover Make sure that the setup pilot cover is installed over the pilot assembly before adding glass
2
Spread an even layer of crushed glass over the media tray and burner. The glass must be only 1 layer thick
on the burner but can be 2 layers thick on the media tray. Make sure no glass is in the pilot area indicated
in the picture below.
© Travis Industries
Installation
(for qualified installers only)
42 ProBuilder
54 ProBuilder
Quantity of Crushed Glass
5 lbs. (2.3 Kg)
6 lbs. (2.7 Kg)
No glass in
this area.
4/12/18 - 1453
53
PB 42 & 54 MV/GSB2 Install