PROBLEM
CAUSE
The stove is at its
Ambient temperatu-
highest power but
re reached.
does not heat up.
Stove running and
display showing
Reached fume outlet
"Smoke Overtepe-
limit temperature
rature"
The stove's smoke
Low smoke tempe-
duct produces
rature
condensation
Stove running and
Routine maintenan-
display showing
ce alert (it does not
"SERVICE"
block the system)

11.2 PROBLEM SOLVING (THERMOSTOVE)

PROBLEM
POSSIBLE CAUSES SOLUTIONS
Thermostat set to
the minimum
Room thermostat
in a position that
In automatic
always detects cold.
position, the boiler
always works at
Faulty temperature
maximum power
detection probe.
Faulty circuit board
Power failure
Blown fuse
The boiler does not
start
Clogged smoke duct
or exhaust
Water temperature
probe has tripped
43
new RIVER IDRO T2 - TESIS Airtight T2 - MIRA T2 - MAYA idroT2
SOLUTION
The stove is at its minimum value. Increase the desired ambient
temperature.
The stove runs at minimum. NO PROBLEM!
Check that the flue is not clogged.
Increase stove power to minimum (pellet drop and fan revs).
Install condensation collection cup.
When this flashing message appears upon start-up, it means that
the preset operating hours have elapsed before maintenance.
Contact the service centre.
Reset the thermostat temperature.
Change the position of the thermostat
Check and, if necessary, replace the probe
Replace board
Make sure the power cable is plugged in and the main switch is in
the "I" position.
Replace the fuse.
Clean the smoke exhaust and/or smoke duct.
Call customer service