Problem Solving (Thermostove) - Cadel IDRO PRINCE3 12 Installer Manual

Hide thumbs Also See for IDRO PRINCE3 12:
Table of Contents

Advertisement

16.2 PROBLEM SOLVING (THERMOSTOVE)

PROBLEM
POSSIBLE CAUSES SOLUTIONS
Thermostat set to
the minimum
Room thermostat
in a position that
In automatic
always detects cold
position, the boiler
always works at
Faulty temperature
maximum power
detection probe
Defective or broken
control panel
Power outage
Blocked pellet
probe
Broken fuse
The boiler does not
start
Broken manostat
(block signal)
Clogged smoke
duct or exhaust
Water temperature
probe has tripped
32
Reset the thermostat temperature
Change the position of the thermostat
Check and, if necessary, replace the probe
Check and, if necessary, replace the panel
Make sure the power cable is plugged in and the main switch
is in the "I" position.
Release it via the rear thermostat. If it happens again, call
customer service.
Replace the fuse
Low water pressure in the boiler
Clean the smoke exhaust and/or smoke duct
Call customer service
INTERVENTION
IDROSTUFE