Room Fan Cleaning; Fume Pipes Annual Cleaning; Gasket Replacement; In Case Of Anomaly - Cadel AMARANTO 9 Installer Manual

Hide thumbs Also See for AMARANTO 9:
Table of Contents

Advertisement

Fig. 76 - Clean with pipe cleaner
• Clean with a pipe cleaner and suction any ash accumulated inside (see Fig. 76 and Fig. 77).
7.4

ROOM FAN CLEANING

Clean every the year the room fan from ash or dust which can cause a blade unbalance and a greater noise.
• Remove the sides. (see Fig. 78).
• Remove dust build-up using a brush or a vacuum cleaner (see Fig. 79).
Fig. 78 - Room fan cleaning (Atena
7.5

FUME PIPES ANNUAL CLEANING

Clean annually from soot with brushes.
The cleaning operation must be executed by a specialized stove-repairer who will provide for the cleaning of fume pipe, chimney
flue and chimney pot. He will also check their eficiency and will release a written declaration of the safety of the appliance. This
operation must be executed at least once a year.
7.6

GASKET REPLACEMENT

In case of deterioration of fire door, hopper or fume chamber gaskets, it is necessary to replace them by an autorized technician in
order to guarantee the good running of the stove.
Use exclusively original spare parts.
8

IN CASE OF ANOMALY

8.1

PROBLEM SOLVING

Before of every Authorized Technician intervention, the same Technician has the duty to check if the parame-
ters of the mother board correspond to those of the table you own.
28
Plus 12/14 - Duke 12/14 At - Saba
3
12/14)
Fig. 77 - Vacuum out the ash
Fig. 79 - Room fan cleaning (Mithos
CRISTAL 9 - CRISTAL PLUS 9 - ICON PLUS 9 - AMARANTO 9 - LIFE 9 - STEEL 9 - ELANE 9