Recommended - Siemens SITRANS Probe LU240 Compact Operating Instructions

Ultrasonic level transmitters
Table of Contents

Advertisement

NOTICE
Direct sunlight
Damage to device.
The device can overheat or materials become brittle due to UV exposure.
• Protect the device from direct sunlight.
• Make sure that the maximum permissible ambient temperature is not exceeded. Refer to
NOTICE
Mounting location
• Ideally, mount device so that face of transducer is at least 300 mm (1 ft) above the
5.1.1.1

Recommended

• Ambient temperature within –40 to +80 °C (–40 to +176 °F)
• Process temperature within –40 to +85 °C (–40 to +185 °F)
• Environment suitable to the housing rating and materials of construction
• Sound path perpendicular to the material surface
• Display and local buttons easily accessible for programming
• Cable entries easily accessible for wiring
• Sufficient room to open device lid with clear access
• Mounting surface free from vibration
• Place for a laptop computer provided for on-site configuration (optional, as laptop not
required for configuration)
NOTICE
Device rotation
The device can be rotated separate from the process connection.
• There is no limit to the number of times device can be rotated without damage.
SITRANS Probe LU240 with mA/HART
Compact Operating Instructions, 09/2021, A5E42673704-AE
the information in Technical specifications (Page 47).
highest anticipated material level.