Diagnostic Procedure For Each Check Code (Hot Water Module) - Toshiba MMW-AP0481CHQ-E Service Manual

Hot water module high temperature type
Hide thumbs Also See for MMW-AP0481CHQ-E:
Table of Contents

Advertisement

8-5. Diagnostic Procedure for Each Check Code (Hot water module)

Check code
Check code name
Flow switch operation
(H-HWM)
[A01]
Dose flow SW
operate ?
YES
Are parts of flow SW
normal ?
YES
Dose water pump
operate ?
YES
Flow switch trouble
Water pump trouble
Clogging of water pipe
H-HWM control P.C. board trouble
H-HWM I/F P.C. board trouble
N
O
Is circuit wiring
normal ?
NO
NO
Is circuit wiring
normal ?
Is H-HWM I/F P.C.
board normal ?
– 65 –
Cause
N
O
YES
NO
YES
NO
YES
(Check there is no clogging in water pipe.)
Check and correct
wiring.
Check H-HWM
control P.C. board.
Check parts.
Check and correct
wiring.
Replace H-HWM
I/F P.C. board.
Check water pump
Failure → replace
Water pipe clogging.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mmw-ap0481chq-tr

Table of Contents