15 - TECHNICAL AND ELECTRICAL CHARACTERISTICS
c.pCOe expansion modules
TECHNICAL CHARACTERISTICS
Storage conditions
Operating conditions
Protection index
Environmental pollution
Classifi cation according to protection against electric shocks
Period of electric stress across the insulating parts
Type of relay action
Type of disconnection or microswitching
Category of resistance to heat and fi re
Immunity from voltage surge
Software class and structure
Dimensions: Length x height x width
ELECTRICAL CHARACTERISTICS
Power supply
Basic model maximum power consumption
Enhanced model maximum power consumption
Maximum connector voltage (NO1...C6)
Meaning of the LEDs
Yellow LED
Green LED
Universal channels
Number
Analogue / digital conversion
Type of input selectable
Type of output selectable
Maximum current output
Precision of analogue input reading
Analogue output precision
Digital outputs
Number
Group 1 (R1, R2); Group 2 (R3, R4, R5)
Group 3 (R6)
Single-pole valve output (Enhanced model only)
Number / type
Maximum output
Connector
Power supply
Maximum current:
Minimum winding resistance
-40T70 ºC; %HR 90 non-condensing
-20T70 ºC; %HR 90 non-condensing
IP40 only on the front panel
Level 3
To be incorporated in class I and/or II appliances
Long
1C
Micro-switch for all of the relay outlets
Category D
Category III
Class A
110 x 70 x 60 mm (4 DIN modules)
24 Vca +10/-15% 50/60 Hz, 28 to 36 Vdc +10/-15%, 15 VA / 6 W
15 VA / 6 W
30 VA / 12 W
250 Vac
fl ashing when setting the address (setting the off set);
on in the event of incorrect address setting
fl ashing if BMS port communication online, on steady if offl ine.
10
14 bits
NTC, PT1000, PT500, PT100, 4 to 20 mA, 0 to 1 V, 0 to 5 V, 0 to 10 V, 0 to 2 kHz (resolution
±1Hz) on/off or open collector digital input (2 kOhm)
PWM 0/3.3 V 100 Hz, PWM 0/3.3 V, 2 mA 2 kHz, 0 to 10 V analogue output
2 mA
± 0,3% of full scale
± 2% of full scale
6
2(1) A (100,000 cycles); UL60730: 5 A resistive, 250 Vac, 30k cycles, 105°C,Defi ned Purpose,
1FLA, 6LRA, 250 Vac, 30k cycles, 105°C, pilot duty C300, 250 Vac, 30k cycles, 105°C.
1(1) A (100,000 cycles) Maximum switchable voltage: 250 Vac; UL 60730-1: 1 A resistive, 1 A
FLA, 6 A LRA, 250 Vac, D300 pilot duty, 30,000 cycles.
1 / single-pole
8 W
6-pin, fi xed sequence
13 Vdc ±5%
0.35 A for each winding
40 Ω