13 - LIST OF CONTROL PARAMETERS WITH "ACCESS LEVEL 1"

Important: All parameters of level "1" are visible to the fi nal user without any password. Parameters with levels of access "2" and "3" are
protected by passwords and they can be found in the complete brochure of the Vectic control (No.10186).
Parameters of "Unit Status"
Screen Parameter
P01
PLAN_ADDRESS
P01
HORA
P01
MINUTO
P01
MODO_VENT
P01
MODO_FRIO
P01
GLOBAL_ALARM
P01
TEMP_INT
P01
TEMP_EXT
P01
HUM_INT
P01
ESTADO_EQUIPO
P01
EN_FASE_HOR_NUEVA
P01
DESHUMIDIFICA
P01
HUMIDIFICA
P01
ON_COMPENSACION
P01
ON_DESESCARCHE
P01
ON_FREECOOL
P01
ON_FREEHEAT
P01
LAMP_COMPRESOR
P01
LAMP_VINT
P01
LAMP_RESISTENCIA
P01
ON_LIMITE_TEMP_IMPULSION Indication of unit in operation with limit of supply temperature
P02
HORA
P02
MINUTO
P02
DIA
P02
MES
P02
ANO
P02
MODO_FRIO
P02
MODO_VENT
P02
GLOBAL_ALARM
P02
SET_TEMP_DISPLAY
P02
ESTADO_EQUIPO
P02
EN_FASE_HOR_NUEVA
P02
DESHUMIDIFICA
P02
HUMIDIFICA
P02
ON_COMPENSACION
P02
ON_DESESCARCHE
P02
ON_FREECOOL
P02
ON_FREEHEAT
P02
LAMP_COMPRESOR
P02
LAMP_VINT
P02
LAMP_RESISTENCIA
P02
ON_LIMITE_TEMP_IMPULSION Indication of unit in operation with limit of supply temperature
P03
PLAN_ADDRESS
P03
HAB_SUPERVISION
P03
TIPO_PROT_COM
P03
BMS_ADDRESS
P03
BAUD_RATE
P03
Stop_bits_Number_MB
P03
Parity_Type_MB
P04
MODELO_EQUIPO
P04
INFO_EQUIPO_1
P04
INFO_EQUIPO_2
P04
UNICO_VOL_AIRE_EXT_CIRC_2 Selection of single-volume of outdoor air in 2-circuits units
P04
TIPO_VENT_EXT
P04
INFO_EQUIPO_3
P04
TIPO_REFRIGERANTE
P04
NUM_WO_DIG_1
P04
NUM_WO_DIG_2
F
MODES
Description of the parameter
Address of the unit in the pLAN local network
Clock: hour
Clock: minute
VENTILATION operating mode
COOLING operating mode
Signal of active alarms
Indoor temperature for regulation of the unit
Temperature of the outdoor air
Indoor relative humidity for regulation of the unit
Unit status (ON, OFF, remote OFF, OFF by phase)
Indication of unit switch-on by schedule programming
Indication of active dehumidifi er
Indication of active humidifi er
Indication of active compensation
Indication of active defrosting
Indication of active free-cooling
Indication of active free-heating
Indication of compressors in operation
Indication of supply fans in operation
Indication of electrical heaters in operation
Clock: hour
Clock: minute
Clock: day
Clock: month
Clock: year
VENTILATION operating mode
COOLING operating mode
Signal of active alarms
Active setpoint temperature
ON/OF unit status
Indication of unit switch-on by schedule programming
Indication of active dehumidifi er
Indication of active humidifi er
Indication of active compensation
Indication of active defrosting
Indication of active free-cooling
Indication of active free-heating
Indication of compressors in operation
Indication of supply fans in operation
Indication of electrical heaters in operation
Address of the unit in the pLAN local network
Enabling the supervision serial card (optional)
Supervision protocol (Carel, Modbus)
Address of the unit in the supervision network
Bits rate (0=1200, 1=2400, 2=4800, 3=9600, 4=19200, 5=38400)
Number of stop bits for the MODBUS protocol (0 = 2 stop bits, 1= 1 stop bit) 0
Type of parity (no parity, odd or even)
Unit model
Unit information: air-air, cooling-only, reversible
Unit information: compressors-circuits (0,2c-1c,4c-2c) + recovery
Type of outdoor fan (3= 2 speeds axial fan; 4= electronic axial fan or plug-fan) 4
Unit information: with electrical heaters - gas burner/boiler - hot water coil
Type of refrigerant (4=R410A, 5=R-454B)
Work order number of the unit (digit 1)
Work order number of the unit (digit 2)
Value Min. Max. UOM Type
0
0
0
---
Integer R
0
0
0
h
Integer R
0
0
0
min
Integer R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0.0
-99.9 0.0
°C
Analog. R
0.0
-99.9 0.0
°C
Analog. R
0.0
0.0
0.0
%rH
Analog. R
0
0
0
---
Integer R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
0
h
Integer R
0
0
0
min
Integer R
0
0
0
day
Integer R
0
0
0
month Integer R
0
0
0
year
Integer R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0.0
0.0
0.0
°C
Analog. R
0
0
0
---
Integer R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
1
---
Digital R
0
0
0
---
Integer R
1
0
1
---
Digital R
1
0
0
---
Integer R
1
0
0
---
Integer R
4
0
4
---
Integer R
0
1
---
Digital R
0
0
2
---
Integer R
0
0
99
---
Integer R
1
0
9
---
Integer R
1
0
99
---
Integer R
0
0
1
---
Digital R
1
4
---
Integer R
1
0
9
---
Integer R
4
0
5
---
Integer R
0
0
9
---
Analog. R
Analog. R
0
0
9
---
Add.
R/W
BMS
48
47
236
14
26
291
2
5
304
22
183
184
185
238
48
47
49
50
51
236
26
22
183
184
185
238
50
227
228
229
282
230
58
191
192
1
193
43
185
186
31