Carrier 50FC User Manual page 38

Electronic control
Table of Contents

Advertisement

13 - LIST OF CONTROL PARAMETERS WITH "ACCESS LEVEL 1"
Parameters of "Input/Output" (...continuation)
Screen Parameter
I08a
DIN_OFF_4ET
I08a
DIN_OFF_RES
I08b
DIN25_DEBUG
I08b
DIN26_DEBUG
I08b
DIN27_DEBUG
I08b
DIN28_DEBUG
I09
COMPRESOR_1
I09
COMPRESOR_1_2
I09
COMPRESOR_2
I09
COMPRESOR_2_2
I09a
RES_ELECTRICA_1_O_VALV
I09a
RES_ELECTRICA_2
I10
OUT_VIC1
I10
OUT_VIC2
I10
VENTILADOR_EXT_1
I10
VENTILADOR_EXT_2
I10b
DOUT18
I10b
DOUT19
I10b
DOUT20
I10b
DOUT21
I10c
DOUT22
I10c
DOUT23
I10c
DOUT24
I10c
DOUT25
I11
ON_VENTILADOR_INT
I11
OUT_07
I12
AOUT_COMPUERTA
AOUT_VALV_O_RES_
I12
PROP_O_HUMIDIF
I12a
AOUT_VEN_EXT1
I12a
AOUT_VEN_EXT2
I12b
AOUT6
I12c
AOUT7
I12d
SET_PRES_DIF_IMP
I12d
PRES_DIF_IMP
I12e
ACTIVAR_FBC1
I12e
DEMANDA_ACTIVAR_FBC1
I15
VOLTAGE_L1_L2
I15
VOLTAGE_L3_L1
I15
VOLTAGE_L3_L1
I15
VOLTAGE_L2
I15
VOLTAGE_L2
I15
VOLTAGE_L3
I16
CURRENT_L1
I16
CURRENT_L2
I16
CURRENT_L3
TYPE_INDUCTIVE_O_
I16
CAPACITIVE
I16
POWER_FACTOR
I16
FREQUENCY
I17
REACTIVE_POWER_L1
I17
REACTIVE_POWER_L2
I17
REACTIVE_POWER_L3
38
Description of the parameter
Status of digital input 23: disconnection of 4 compressor stages
Status of digital input 24: disconnection of electrical heaters
Status of digital input 25: opening of supply damper of zone 1
Status of digital input 26: opening of supply damper of zone 2
Status of digital input 27: opening of return damper of zone 1
Status of digital input 28: opening of return damper of zone 2
Status of contactor of compressor 1 circuit 1
Status of contactor of compressor 2 circuit 1
Status of contactor of compressor 1 circuit 2
Status of contactor of compressor 2 circuit 2
Status of contactor of 1st stage of electrical heaters or gas burner or gas
boiler or hot water coil valve
Status of contactor of 2nd stage of electrical heaters
Status of cycle reversing valve of circuit 1
Status of cycle reversing valve of circuit 2
Status of outdoor fan(s) of circuit 1
Status of outdoor fan(s) of circuit 2
Status of digital output 18: electical heating for the piping layout of the water
circuit with GREAT COLD or confi gurable output (humidifi er, HWC pump,
alarm signal,...)
Status of digital output 19: compressor with supplementary crankcase heater 0
Status salida digital 20: electrical heater for protection of fresh air damper
or solenoid valve SV1 with actve dehumidifi cation
Status of digital output 21: confi gurable output (humidifi er, HWC pump, alarm
signal,...) or solenoid valve SV2 with actve dehumidifi cation
Status of digital output 22: supply damper of zone 1
Status of digital output 23: supply damper of zone 2
Status of digital output 24: return damper of zone 1
Status of digital output 25: return damper of zone 2
Status of indoor unit supply fan
Status of output NO7 in which one of the following options can be connected:
on-off humidifi er, circulation pump of the hot water coil, boiler pump, rotary
heat exchanger or remote alarm signal
Display of opening % of fresh air damper (optional). Range vary between
0% (0V) and 100% (10V)
Display of opening % of : HWC heat valve or proportional electrical heater or
proportional humidifi er or gas burner/boiler or overpressure damper
Display of operating % of electronic outdoor fan(s) of circuit 1
Display of operating % of electronic outdoor fan(s) of circuit 2
Display of % proportional humidifi er or exhaust damper or 3-way valve (3-WV)
of the condensation coil with active dehumidifi cation
Display of operating % of the wheel (variable rotary heat exchanger) or
preheater with electrical heater
Diff erential pressure sensor setpoint for constant supply pressure
Diff erential pressure sensor reading for constant supply pressure
Display of operation of the condensate pump
Condensate pump operating demand
Reading of the energy meter: voltage between phases L1-L2
Reading of the energy meter: voltage between phases L2-L3
Reading of the energy meter: voltage between phases L3-L1
Reading of the energy meter: voltage between phase and neutral L1
Reading of the energy meter: voltage between phase and neutral 2
Reading of the energy meter: voltage between phase and neutral 3
Reading of the energy meter: phase current L1
Reading of the energy meter: phase current L2
Reading of the energy meter: phase current L3
Inductive character L (0) or capacitive character C (1) of the equivalent
electrical load of the unit
Reading of the energy meter: power factor
Reading of the energy meter: frequency
Reading of the energy meter: reactive power phase L1
Reading of the energy meter: reactive power phase L2
Reading of the energy meter: reactive power phase L3
E
INPUTS/OUTPUTS
Value Min.
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0.0
0.0
0.0
200
0
0
0
0
0
0
0
0
0
0.0
0.0
0.0
0
0
0.0
0.0
0.0
0.0
Max. UOM Type
R/W
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0
1
---
Digital R
0.0
100.0 ---
Analog. R
0.0
100.0 ---
Analog. R
0.0
100.0 ---
Analog. R
0.0
100.0 ---
Analog. R
0.0
100.0 ---
Analog. R
0.0
100.0 ---
Analog. R
0
10000 Pa
Integer R
-99999 99999 Pa
Integer R
0
1
---
Digital R
0
1
---
Digital R
-9999
9999 V
Integer R
-9999
9999 V
Integer R
-9999
9999 V
Integer R
-9999
9999 V
Integer R
-9999
9999 V
Integer R
-9999
9999 V
Integer R
-999.9 999.9 A
Analog. R
-999.9 999.9 A
Analog. R
-999.9 999.9 A
Analog. R
0
1
---
Digital R
0
32
---
Integer R
-999.9 999.9 Hz
Analog. R
-999.9 999.9 kVAR Analog. R
-999.9 999.9 kVAR Analog. R
-999.9 999.9 kVAR Analog. R
Add.
BMS
16
76
17
77
20
21
18
19
23
24
15
10
11
12
13
292
291
167
168
169
170
171
172
131
132
133
334
173
142
134
135
136

Advertisement