Daikin EPRA14DAW1 Installer's Reference Manual page 34

Hide thumbs Also See for EPRA14DAW1:
Table of Contents

Advertisement

5
|
Application guidelines
Underfloor heating or radiators – Multiple external room thermostats
Installer reference guide
34
For more information about connecting the electrical wiring to the unit, see:
-
"8.2 Connections to the outdoor
-
"8.3 Connections to the indoor
The underfloor heating of the main room is directly connected to the indoor unit.
The room temperature of the main room is controlled by the dedicated Human
Comfort Interface (BRC1HHDA used as room thermostat).
A thermostatic valve is installed before the underfloor heating in each of the
other rooms.
INFORMATION
Mind situations where the main room can be heated by another heating source.
Example: Fireplaces.
Configuration
Setting
Unit temperature control:
#: [2.9]
Code: [C-07]
Number of water temperature zones:
#: [4.4]
Code: [7-02]
Benefits
Easy. Same installation as for one room, but with thermostatic valves.
Setup
A Main leaving water temperature zone
B Room 1
C Room 2
a External room thermostat
b Bypass valve
For more information about connecting the electrical wiring to the unit, see:
-
"8.2 Connections to the outdoor
-
"8.3 Connections to the indoor
For each room, a shut-off valve (field supplied) is installed to avoid leaving water
supply when there is no heating or cooling demand.
4
unit" [
 92]
4
unit" [
 99]
2 (Room thermostat): Unit operation
is decided based on the ambient
temperature of the dedicated Human
Comfort Interface.
0 (Single zone): Main
B
C
A
M1
M2
a
a
4
unit" [
 92]
4
unit" [
 99]
EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G)
Value
b
Daikin Altherma 3 H HT F
4P587502-1A – 2020.01

Advertisement

Table of Contents
loading

Table of Contents