Piping Diagram: Outdoor Unit - Daikin EPRA14DAW1 Installer's Reference Manual

Hide thumbs Also See for EPRA14DAW1:
Table of Contents

Advertisement

15.2 Piping diagram: Outdoor unit

d
k
i
i
R5T
j
Gas
Gas
Liquid
Liquid
a
Water IN (screw connection, male, 1")
b
Water OUT (screw connection, male, 1")
c
Plate heat exchanger
d
Pinched pipe
e
Refrigerant filter
f
One-way valve
g
Economiser heat exchanger
h
Service port 5/16" flare
i
Capillary tube
j
Distributor
k
Air heat exchanger
l
PCB cooling
m
Accumulator
n
Muffler
E1HHEX
Plate heat exchanger heater
M1C
Compressor
M1F
Fan motor
S1PH
High pressure switch (5.6 MPa)
S2PH
High pressure switch (4.17 MPa)
S1PL
Low pressure switch
S1NPH
High pressure sensor
Y1E
Electronic expansion valve (main)
Y3E
Electronic expansion valve (injection)
Y1S
Solenoid valve (4-way valve)
Y2S
Solenoid valve (low pressure bypass)
Y3S
Solenoid valve (hot gas bypass)
Y4S
Solenoid valve (liquid injection)
EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G)
Daikin Altherma 3 H HT F
4P587502-1A – 2020.01
h
*
l
Y4S
M1F
i
i
S1PL
m
Y1E
e
f
f
g
Y3E
sv
Y2S
Y1S
sv
Y3S
n
n
R2T
R7T
R8T
M1C
Thermistors:
R1T
Outdoor air
R2T
Compressor discharge
R3T
Compressor suction
R4T
Air heat exchanger, distributor
R5T
Air heat exchanger, middle
R6T
Refrigerant liquid
R7T
Compressor shell
R8T
Compressor port
R9T
Entering water
R10T
Leaving water
Refrigerant flow:
Heating
Cooling
15
|
e
f
f
d
Gas
Liquid
S1NPH
e
S1PH
*
1N~
3N~
Technical data
c
R10T
b
a
R9T
l
3D124079C
Installer reference guide
233