9
|
Configuration
Quiet
Electricity prices and gas price
Installer reference guide
172
About quiet mode
You can use quiet mode to decrease the sound of the outdoor unit. However, this
also decreases the heating/cooling capacity of the system. There are multiple quiet
mode levels.
The installer can:
Completely deactivate quiet mode
Manually activate a quiet mode level
Enable the user to program a quiet mode schedule
If enabled by the installer, the user can program a quiet mode schedule.
INFORMATION
If the outdoor temperature is below zero, we recommend to NOT use the most quiet
level.
To check if quiet mode is active
If
is displayed on the home screen, quiet mode is active.
To use quiet mode
1 Go to [7.4.1]: User settings > Quiet > Activation.
2 Do one of the following:
If you want to...
Completely deactivate quiet
mode
Manually activate a quiet
mode level
Enable the user to program a
quiet mode schedule
Only applicable in combination with the bivalent function. See also
4
"Bivalent" [
 189].
#
Code
[7.5.1]
N/A
Then...
Select Off.
Result: The unit never runs in quiet
mode. The user cannot change this.
Select Manual.
Go to [7.4.3] Level and select the
applicable quiet mode level.
Example: Most quiet.
Result: The unit always runs in the
selected quiet mode level. The user
cannot change this.
Select Automatic.
Result: The unit runs in quiet mode
according to a schedule. The user
(or you) can program the schedule
in [7.4.2] Schedule. For more
information about scheduling, see
"9.3.7 Schedule screen:
4
Example" [
 126].
Description
Electricity price > High
EPRA14~18DAV3+W1 + ETVH/X16S18+23DA6V+9W(G)
Daikin Altherma 3 H HT F
4P587502-1A – 2020.01