Appendix
#
Maintenance work
26
Check and, if required, replace the insulating mat in the burner area
27
Installing the gas-air mixture unit
28
Reassemble the product
29
Open the service valves, carry out the required leak-tightness test
30
Fill the product/heating installation to the filling pressure specified for the
system
31
Connect the product to the electrical installation
32
Run the test operation on the product/heating installation including hot
water generation (if available) and, if required, purge the product/heating
installation
33
Record all of the analysis results in the Benchmark service record in
these instructions
G
Position of the opening in the air/flue pipe
J
G.1

Positioning of the opening of a fan-supported flue gas pipe

Installation site
A
Directly below an opening, air bricks, opening windows, etc., that can be opened.
B
Above an opening, air bricks, opening windows, etc., that can be opened.
C
Horizontally to an opening, air bricks, opening windows, etc., that can be opened.
Below temperature-sensitive building components, e.g. plastic gutters, down pipes or wastewater
D
pipes
E
Below eaves
F
Below balconies or car port roofs
G
From vertical wastewater pipes or down pipes
H
From external or internal corners
I
Above floors, roofs or balconies
J
From a surface facing a terminal
K
From a terminal facing a terminal
L
From an opening in the car port (e.g. door, window) which leads into the dwelling
38
P
D, E
O
B
C
A
G
I I
Installation and maintenance instructions ecoFIT sustain 0020277252_00
Interval
If required, at least every
5 years
If required, at least every
5 years
After each time maintenance
work is carried out
Annually
Annually
Annually
Annually
Annually
N
N
Minimum dimen-
sions
300 mm
300 mm
300 mm
75 mm
200 mm
200 mm
150 mm
200 mm
300 mm
600 mm
1,200 mm
1,200 mm
27