A
Overview of diagnostics codes
Note
Since the code table is used for various products, some codes may not be visible for the product in question.
Dia-
gnostics
Parameter
code
d.00
Heating maximum output
d.01
Pump overrun in heating
mode
d.02
Maximum burner anti-
cycling time in heating
mode
d.04
Water temperature in the
cylinder
d.05
Determined heating flow
set target temperature
d.06
Hot water set target tem-
perature
d.07
Set target temperature
for the domestic hot wa-
ter cylinder
d.08
Status of the 230 V ther-
mostat
d.09
Heating flow set target
temperature that is set
on the eBUS room ther-
mostat
d.10
Status of the internal
pump in the heating cir-
cuit
d.11
Status of the heating
circuit's shunt pump
d.13
Status of the hot water
circuit's circulation pump
d.14
Operating mode of the
modulating pump
d.15
Pump speed
d.16
Status of the 24 V room
thermostat
d.17
Heating control
28
Values
Unit
Increment, select, explanation
Min.
Max.
kW
The maximum heating output
varies depending on the product.
→ Section "Technical data"
Automatic: Unit automatically
adjusts the maximum output to
the current system demand
1
60
min
1
2
60
min
1
Current value
Current value
Current value
(Combination unit only)
Current value
Current value
0 = Room thermostat open (no
heat requirement)
1 = Room thermostat closed
(heat requirement)
Current value
Current value
off / on
Current value
off / on
Current value
off / on
0
5
0 = variable rotational speed
(auto)
1; 2; 3; 4; 5 = Fixed rotational
speeds → Section "Setting the
pump output"
Current value
%
Current value
off = Heating off
on = Heating on
off = Flow temperature
on = Return temperature (ad-
justment for underfloor heating.
If you have activated the return
temperature control, the auto-
matic heating output determina-
tion function is not active.)
Installation and maintenance instructions ecoFIT sustain 0020277252_00
Default set-
Own setting
ting
→ Section
Adjustable
"Technical
data"
5
Adjustable
20
Adjustable
Not
adjustable
Not
adjustable
Not
adjustable
Not
adjustable
Not
adjustable
Not
adjustable
Not
adjustable
Not
adjustable
Not
adjustable
0
Adjustable
Not
adjustable
Not
adjustable
0
Adjustable