Checking Leak-Tightness; Adapting The Unit To The Heating Installation; Burner Anti-Cycling Time - Vaillant ecoFIT sustain 615 Installation And Maintenance Instructions Manual

Hide thumbs Also See for ecoFIT sustain 615:
Table of Contents

Advertisement

1
3.
Unscrew the cover from the flue gas analysis point (1).
4.
Measure the CO₂ content at the flue gas analysis point
(1).
5.
Compare the measured value with the corresponding
value in the table.
Checking the CO₂ content
Great Britain
front casing on / front casing off
Natural gas
G20
9.2 ±1 %
The value is OK.
The value is not OK; you cannot start up the
product.
Inform Customer Service.
7.12

Checking leak-tightness

Check the gas pipe, the heating circuit and the hot water
circuit for leak-tightness.
Check that the air/flue pipe has been installed correctly.
Conditions: Room-sealed operation
Check whether the vacuum chamber has been closed
tightly.
7.12.1 Checking the heating mode
1.
Activate the heating mode on the user interface.
2.
Turn all thermostatic radiator valves on the radiators
until they are fully open.
3.
Allow the product to operate for at least 15 minutes.
4.
Fill and purge the heating installation. (→ Page 16)
5.
Call up the status codes. (→ Page 14)
Status codes – Overview (→ Page 31)
If the product is working correctly, the display shows
S.04.
8
Adapting the unit to the heating
installation
You can reset/change the system parameters.
Overview of diagnostics codes (→ Page 28)
0020277252_00 ecoFIT sustain Installation and maintenance instructions

Adapting the unit to the heating installation 8

8.1

Burner anti-cycling time

To prevent frequent switching on and off of the burner and
thus prevent energy losses, an electronic restart lockout
is activated for a specific period each time the burner is
switched off. The burner anti-cycling time is only active for
the heating mode. Hot water handling mode during a burner
anti-cycling time does not affect the time function element.
8.1.1
Setting the burner anti-cycling time
1.
Navigate to diagnostics code D.002 in the installer level
and confirm by pressing
2.
Set the burner anti-cycling time and confirm by pressing
.
T
Flow
(tar-
get)
[°C]
30
35
40
45
50
55
60
65
70
75
T
Flow
(target)
[°C]
30
35
40
45
50
55
60
65
70
75
8.1.2
Resetting the remaining burner anti-cycling
time
Press
.
Set maximum burner anti-cycling time [min]
1
5
10
15
2.0
4.0
8.5
12.5
2.0
4.0
7.5
11.0
2.0
3.5
6.5
10.0
2.0
3.0
6.0
8.5
2.0
3.0
5.0
7.5
2.0
2.5
4.5
6.0
2.0
2.0
3.5
5.0
2.0
1.5
2.5
3.5
2.0
1.5
2.0
2.5
2.0
1.0
1.0
1.0
Set maximum burner anti-cycling time
[min]
35
40
45
29.0
33.0
37.0
41.0
25.5
29.5
33.0
36.5
22.5
26.0
29.0
32.0
19.5
22.5
25.0
27.5
16.5
18.5
21.0
23.5
13.5
15.0
17.0
19.0
10.5
11.5
13.0
14.5
7.0
8.0
9.0
10.0
4.0
4.5
5.0
1.0
1.0
1.0
.
20
25
30
16.5
20.5
25.0
15.0
18.5
22.0
13.0
16.5
19.5
11.5
14.0
17.0
9.5
12.0
14.0
8.0
10.0
11.5
6.0
7.5
9.0
4.5
5.5
6.5
2.5
3.0
3.5
1.0
1.0
1.0
50
55
60
45.0
49.5
40.5
44.0
35.5
38.5
30.5
33.0
25.5
28.0
20.5
22.5
15.5
17.0
11.0
11.5
5.5
6.0
6.5
1.0
1.0
1.0
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents