Dia-
gnostics
Parameter
code
d.80
Running time in heating
mode
d.81
Running time in hot wa-
ter handling mode
d.82
Number of burner igni-
tions in heating mode
d.83
Number of burner igni-
tions in hot water hand-
ling mode
d.84
Maintenance in
d.85
Increase in the min. out-
put (heating and hot wa-
ter handling mode)
d.88
Flow rate limit value
for ignition in hot water
handling mode
d.90
Status of the eBUS room
thermostat
d.91
Status DCF77
d.93
Setting the product code
d.94
Delete fault list
d.95
Software versions
d.96
Default setting (reset)
Status codes – Overview
B
Note
Since the code table is used for various products, some codes may not be visible for the product in question.
Status code
S.0
Heating mode: No requirement
S.01
Heating mode: Advance fan operation
S.02
Heating mode: Pump pre-run
S.03
Heating mode: Burner ignition
S.04
Heating mode: Burner on
S.05
Heating mode: Pump/fan overrun
S.06
Heating mode: Fan overrun
S.07
Heating mode: Pump overrun
S.08
Heating mode: Temporary shutdown after heating procedure
S.10
Hot water handling mode: Requirement
S.11
Hot water handling mode: Advance fan operation
S.13
Hot water handling mode: Burner ignition
S.14
DHW mode: Burner on
S.15
DHW mode: Pump/fan overrun
0020277252_00 ecoFIT sustain Installation and maintenance instructions
Values
Unit
Increment, select, explanation
Min.
Max.
Current value
h
Running time = Display value x
100
Current value
h
Running time = Display value x
100
Current value
Number of ignitions = Display
value x 100
Current value
Number of ignitions = Display
value x 100
0
3000
h
Number of hours = Display value
x 10
kW
1
0
1
0 = 1.7 l/min (no delay)
1 = 3.7 l/min (2 s delay)
Current value
off = Not connected
on = Connected
Current value
0
99
1
The Device Specific Number
(DSN) can be found on the iden-
tification plate.
0
1
off = No
on = Yes
1 = Main PCB
2 = Interface PCB
0 = No
1 = Yes
Displays in heating mode
Displays in hot water handling mode
Meaning
Appendix
Default set-
Own setting
ting
Not
adjustable
Not
adjustable
Not
adjustable
Not
adjustable
300
Not
adjustable
Adjustable
0
Adjustable
Not
adjustable
Not
adjustable
Adjustable
Adjustable
Adjustable
Adjustable
31