  • Page 1 Cooker hood or appliance name Users Guide & Installation Instructions Instruction Number www. rangemaster. co. uk COD. 01063GB - 30.05.2002...
  • Page 2 DESCRIPTION OF THE HOTPLATES MODELS: 58580 / 58620 1 Ultra rapid burner 2 Rapid gas burner 3 Semi rapid gas burner 4 Auxiliary gas burner 5 Two burner enamelled steel pan support 6 Central enamelled steel pan support (for ultra rapid burner) 7 Burner n°...
  • Page 3 1) BURNERS The diagram on the front panel next to each knob shows which burner it controls. To light a burner make sure that the gas is turned on and then: - Automatic electrical ignition Push and turn the knob corresponding to the required burner in an anticlockwise direction until it reaches the full on position (large flame fig.
  • Page 4 Notes: Use of a gas cooking appliance produces heat and moisture in the room in which it is installed. The room must therefore be well ventilated by keeping the natural air vents clear (fig. 3) and by activating the mechanical aeration device (suction hood or electric fan fig. 4 and fig. 5). Intensive and lengthy use of the appliance may require additional ventilation.
  • Page 5 IMPORTANT Always disconnect the appliance from the gas and electricity mains before carrying out any cleaning operation. 2) HOTPLATE Periodically wash the hotplate, the enamelled steel pan support, the enamelled burner caps "C" and the burner heads "T" (see fig. 6) with lukewarm soapy water.
  • Page 6: Installation

    TECHNICAL INFORMATION FOR THE INSTALLER This appliance shall be installed in accordance with the regulations in force and only in a well-ventilated space. Read the instructions before installing or using this appliance. In the UK the regulations and standards are as follows: - In your own interest and that of safety, it is law that all gas appliances be installed by...
  • Page 7: Room Ventilation

    IMPORTANT INSTALLATION INSTRUCTIONS The rear wall, the surfaces surrounding and adjacent to the appliance must be able to withstand a temperature rise of 75ºC. The adhesive used to stick the plastic laminate to the cabinet must be able to withstand a temperature of not less than 150ºC otherwise the laminate could come unstuck.
  • Page 8 WARNINGS: Remember that the gas inlet union on the appliance is a 1/2” gas parallel male type in compliance with ISO 228-1 standards. The installer must ensure that the gas supply pipe is never able to touch moveable parts of the built-in cabinet (e.g.
  • Page 9: Electrical Connection

    8) ELECTRICAL CONNECTION Electrical connection must be carried out in compliance with the standards and regulations in force. Before proceeding with the connections, check that: - The voltage and power rating of the supply is suitable for the maximum power draw of the appliance (see data label fixed to the bottom of the appliance).
  • Page 10 Always disconnect the appliance from the electricity mains before making any adjustments. All seals must be replaced by the technician at the end of any adjustments. The burners do not require primary air adjustment. 9) TAPS The gas taps are male conical type, suitable for all gases.
  • Page 11: Replacing The Injectors

    10) REPLACING THE INJECTORS The burners can be converted to different types of gas by changing the injectors. To do this, first remove the burner tops. Unscrew the injector "A" (see fig. 13). See the table for the correct injector size. Fit the new injector and screw it down hard.
  • Page 12 Always disconnect the appliance from the electricity and gas mains before servicing. 11) REPLACING HOTPLATE PARTS Remove the pan supports and the burner tops. Remove the burner fixing screws "V" (fig. 14). Pull off the control knobs. Lift off the hotplate top. The burners (fig.15), taps (fig.
  • Page 13 SERVICING CABLE TYPES AND SECTIONS TYPE OF TYPE OF SINGLE - PHASE HOTPLATE CABLE POWER SUPPLY Gas hotplate H05 RR - F Section 3 X 0.75 mm ATTENTION!!! If the power supply cable is replaced, the installer should leave the earth wire longer than the other conductors (fig.
  • Page 14 TECHNICAL DATA ON THE DATA LABEL 4 BURNERS Category = II 2H3+ Butane = 28 - 30 mbar Propane = 37 mbar Natural = 20 mbar Tot. Nom. Gas Rate = 7.3 kW Tot. Nom. L.P.G. Rate = 531 g/h Voltage = 230 V ˜...
  • Page 15: Technical Assistance And Spare Parts

    TECHNICAL DATA FOR THE APPLIANCE GAS REGULATION TECHNICAL ASSISTANCE AND SPARE PARTS Before leaving the factory, this appliance will have been tested and regulated by expert and specialized personnel in order to guarantee the best performances. Only qualified engineers should carry out any repairs or adjustments. Do not use re-conditioned or unauthorized gas controls.