Troubleshooting - Crown GL-40FE Installation & Operation Manual

Gas kettles
Table of Contents

Advertisement

Gas Kettles

Troubleshooting

Loose, broken or grounded wiring may cause many of the symptoms listed.
PROBLEM
Unit will not come on.
Unit will turn on electrically
but will not heat.
Excessive flame rollout on
ignition, carboning.
Unit slow to preheat and slow
to recover.
Unit continuously locks out.
INSTALLATION & OPERATION MANUAL 10199 REV 3 (08/22)
NOTICE
Check all wiring and make sure it is intact.
Power switch is off.
Unit not plugged in.
Main power supply off.
Bad electronic module.
Bad low water control.
Bad spark igniter.
Bad intermittent pilot burner.
Fuse in unit blown.
Lockout has occurred.
Thermostat not on.
Gas control valve off.
Main gas supply off.
Low water.
Bad thermostat.
Bad pressure switch.
Bad gas control valve.
Bad spark igniter.
Bad igniter cable.
Bad intermittent pilot burner.
Faulty gas control.
Natural gas unit on propane.
Excessive gas pressure.
Incorrect orifice size.
Faulty regulator in gas control.
Propane gas on natural.
Low gas pressure.
Incorrect orifice sizes.
Loss of vacuum.
Faulty regulator in gas control.
Pilot gas adjusted too low.
Excessive draft condition.
Excessive steam around bottom of unit during operation of cleaning.
Faulty transformer.
Faulty electronic module.
Faulty ignitor cable.
Faulty spark igniter.
Faulty gas control.
PROBABLE CAUSE
Troubleshooting
21
PAGE
OF32

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gl-60fe

Table of Contents