Troubleshooting - Crown EMT-6 Installation & Operation Manual

Direct steam kettles
Hide thumbs Also See for EMT-6:
Table of Contents

Advertisement

Direct Steam Kettles Mounted on Electric Boiler Cabinet Base

Troubleshooting

Troubleshooting
NOTICE
Contact the factory, the factory representative or local service company to perform maintenance and repairs.
Water Not Being Supplied to Boiler
1. Water supply is "OFF".
2. Defective water fill solenoid.
3. Water level control clogged or defective, unable to operate fill valve.
4. Check drain valve is closed.
5. Supply water pressure too low.
Automatic Blowdown Valve Does Not Drain
1. Defective blowdown valve.
2. Heat exchanger build up of scalant clogging drain lines and valve.
Boiler Achieves Pressure Slower Than Normal
1. Heavy build up of lime on elements.
2. Loose element connections.
Safety Valve Blows
1. Defective safety valve.
2. Pressure too high, pressure switch requires adjustment (lower) or may be defective.
INSTALLATION & OPERATION MANUAL 10071 REV 4 (07/22)
17
PAGE
OF 20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emt-10Emt-12Emt-6-6Emt-10-6Emt-10-10

Table of Contents