Gas Kettles
Service
Disconnect the power supply to the appliance before cleaning or servicing.
General
When any difficulty arises always check that the unit has been connected to the gas supply type and voltage for which it
was supplied. This can be done by examining the serial plate on the lower right side of the unit. It will list the gas type and
voltage for which the unit was manufactured.
Wiring diagrams for the unit are located in a small envelope affixed to the rear side of the front control panel.
GL-40FE
GL-60FE
Manifold Pressure
Natural Gas - 4 inches W.C.
Pilots
The pilot adjustment is part of the combination control valve located just behind the lower front access door. It is located
on the centre left side of the control just below the large slotted screw head. (See Figure 1). Remove the large slotted
screw; below this is a second slotted screw used for adjustment of the pilot burner flame.
Figure 1
INSTALLATION & OPERATION MANUAL 10199 REV 3 (08/22)
UNIT
TOTAL INPUT
130,000 BTU/Hour
150,000 BTU/Hour
LP Gas - 10 inches W.C.
Top view of gas control
WARNING
ORIFICE SIZE
NATURAL
26
30
Service
PROPANE
41
45