Water Connection
On units equipped with an optional water fill valve connect a water line (minimum 1/4") to the valve with a 1/4" NPT female fitting.
Units with dual (hot and cold) valves must have the hot water line connected to side with the hot water valve (red) and cold water
line to the cold water valve (blue). Plastic or rubber hose is not recommended, as it may melt against the hot kettle side.
For an appliance equipped with casters, the installation shall be made with a connector that complies with the
standard for connectors for moveable gas appliances, ANSI Z21.69-CSA 6.16 and a quick-disconnect device that
complies with the standard for quick-disconnect devices for use with gas fuel, ANSI Z21.41-CSA 6.9; adequate
means must be provided to limit the movement of the appliance without depending on the connector and the quick
disconnect device or its associated piping to limit the appliance movement; the location where the restraining
means may be attached to the appliance is on bottom of unit directly below relief valve.
If the unit is also equipped with an optional water fill valve it too must be installed with a flexible water supply tube,
a quick disconnect and strain relief.
Electrical Connection
Do not connect the appliance to the electrical supply until after the gas connection has been made.
This appliance is equipped with a three-prong (grounding) plug for your protection against shock hazard
and should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the
grounding prong from this plug. (120V units only).
1. 120 VAC - 60 Hz - Single Phase
Units with this electrical rating are factory supplied with a three-wire cord and three-prong plug which fits any standard
120V, three-prong grounded receptacle. A separate 15 amp supply is needed for each unit.
2. 208/240 VAC - 60 Hz - Single and Three Phase
Units with this electrical rating are factory equipped with a transformer. To connect supply wires remove cover from
transformer box at right rear of unit. Route supply wires and ground wire through the hole in the cover with a strain relief
fitting. Connect wires to the primary transformer terminals as required by your power supply voltage. Connect ground
wire to ground lug. Replace cover. Three-phase units are wired as above, using only two supply wires. The third supply
wire is not connected and must be properly terminated.
3. 220 VAC - 50 Hz - Single Phase
Units equipped with this voltage rating should be wired exactly as in (Step 2) above.
8
PAGE
OF 32
WARNING
WARNING
WARNING
ELECTRICAL GROUNDING INSTRUCTIONS
INSTALLATION & OPERATION MANUAL 10199 REV 3 (08/22)