Hardware Description

Table 4-6. PRU0 ICSS Gigabit Ethernet PHY Strapping Resistors

Functional Pin
RX_D0
RX_D1
JTAG_TDO/GGPIO_1
RX_D3
RX_D2
RX_LINK
RX_ER
LED_2
RX_DV
For the Industrial Ethernet PHY transceiver:
The Ethernet PHY requires two separate power sources. VDDIO is the 3.3 V, system generated analog
supply. VSYS_IO_3V3 is the 3.3V I/O supply.
The Ethernet PHY is set to ENHANCED mode by pulling the MODESELECT pin up to VDDIO.
– ENHANCED mode allows the DP83826E to support real-time Ethernet applications in addition to standard
Ethernet applications.
The Ethernet PHY uses many functional pins as strap options to place the device into a specific mode of
operation. Each functional pin has a default mode that is driven by an internal pull resistor

Figure 4-13. PRU1 ICSS Industrial Ethernet PHY Strapping Resistors

26
AM263x Control Card Hardware User's Guide
Default Mode
Mode in CC
0
3
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Copyright © 2023 Texas Instruments Incorporated
Function
PHY address: 0011
RGMII to Copper
Auto-negotiation, 1000/100/10 advertised, auto MDI-X
Port Mirroring Disabled
SPRUJ09C – MARCH 2022 – REVISED FEBRUARY 2023
www.ti.com
Submit Document Feedback

Advertisement

Table of Contents
loading

This manual is also suitable for:

Am2631Am2632Am2634Am2632-q1Am2631-q1Am2634-q1

Table of Contents