Toro Grandstand 18562 Operator's Manual page 52

Revolution mower with 48in or 60in turbo force cutting unit
Table of Contents

Advertisement

Problem
SPN 520193, FMI 3
SPN 524032, FMI 3
SPN 520193, FMI4
SPN 524033, FMI 31
SPN 524035 or SPN 524042, FMI 31
SPN 524035 or SPN 524042, FMI 9
Battery-Charger Fault Codes
Problem
SPN 524160, FMI 31
Possible Cause
1. High AC voltage error (>270VAC)
1. Charger failed to initialize
1. Low AC voltage oscillation error
1. Re-programming failed
1. Communication error with battery
1. Communication error with battery
Possible Cause
1. Internal charger fault
52
Corrective Action
1. Connect charger to an AC source that
provides stable AC between 85 - 270
VAC / 45-65 Hz.
1. The charger failed to turn on properly.
Disconnect the AC input and battery
connection for 30 seconds before
retrying.
1. The AC source is unstable. Could
be caused by undersized generator
or severely undersized input cables.
Connect charger to an AC source that
provides stable AC between 85 - 270
VAC / 45-65 Hz.
1. Software upgrade failure or script
operation failure. Ensure that the new
software is correct.
1. Ensure that the connection of the
signal wires to the battery is secure.
1. Ensure that the connection of the
signal wires to the battery is secure.
Corrective Action
1. Remove the AC connection and
battery connection for a minimum of
30 seconds and retry. If it fails again,
please contact an authorized Toro
distributor.