The tests feature is available after setup has been completed once. After
you touch next in the final setup screen, the "select tests to run" screen
(figure 18) will appear. (If you want you may skip tests; touch skip tests.)
To run all of the tests, touch select all. All boxes in the list of tests will be
checked. Or, touch box(es) next to test(s) to run certain tests.
After the tests have been started, the screen will describe which test is
running and shows a diagnostic summary of each test (see figure 19). After
reviewing the results and concluding that no further tests are needed, touch
next to proceed to next test. The technician must verify that the test
procedure is producing the desired result at the equipment.
After pressing next after the final test, the Testing finished screen will
appear (figure 20). At this point, use the EXIT button (if you have completed
the required setup), or use diagnostics button (to analyze the system), or
use equipment button (if you wish to make any changes to device details).
tests
setup
current test: Blower
Check Blower Operation
Heating Rate
Blower CFM Demand
Blower Off Delay
Blower On Delay
Indoor Blower RPM
Indoor Blower Power
Flame Current
Flame Sense
Outdoor Temperature
9:39 am Aug 15, 2012
Figure 19. Typical Tests Results Screens
equipment
alerts
diagnostics
%
1400CFM
Off
Off
0
0.0000%
0.000mA
No Flame
63ºF
cancel
setup
9:39 am Aug 15, 2012
Touch confirm to continue system configuration; the screen will change to
the system discovery screen. At this point, the program goes through the
same setup as the initial setup process which begins on page 3.
NOTE - "Compatible device found" screen (shown below) appears only
when a device has been removed and replaced with a compatible device.
Missing
Device Equipment Type No.
Model No. (control model no.)
Serial No. (control serial no.)
next
19
iComfort Wi‐Fi
tests
equipment
The Testing Process is finished
press 'tests' button to run more tests
press 'EXIT' button to start normal operation
Figure 20. Testing Finished Screen
Found Compatible
Device Equipment Type No.
Model No. (control model no.)
Serial No. (control serial no.)
Settings were not copied
®
7-Day Programmable Communicating Thermostat
diagnostics
alerts
cancel
next

Advertisement