16.4 Export 50Hz J-210 & J-220 Models
This wiring diagram is used for all J-210 & J-220 230V 50Hz Export spa
models.
J1 Logic Jumper Settings
JP1 1-2 ON
JP1 1-2 OFF = 30A Logic
JP1 7-8 ON
JP1 7-8 OFF = °F Temperature Display
Spa Light
Optional
O 3
Ozonator
F1
20A
250V
SC-20
GRN
Hard
Wire
Only
TB1
BLU
BLU
BLU
2
BRN
BRN
BRN
1
= 20A Logic (Factory Setting)
= °C Temperature Display (Factory Setting)
J20
J21
J12
BLK
J14
J16
BRN
F1*
J11
BLU
J15
K5
J5
J13
BRN
J6
Main Pump
BRN
BLU
LO
Standard 3-Wire 230 VAC Connection (50 Hz, 1 Phase Service)
Use copper conductors ONLY. Wire size must be appropriate per NEC and/or
local codes.
J1
8
7
6
5
4
3
2
1
K7
Heater IN
Heater OUT
J9
J17
J7
J8
BLU
BLK
HI
BLU
BRN
J-200 Series
Control
Panel
Temperature Sensor
J2
Hi-limit/Freeze Sensor
J3
Pressure Switch
Transformer
230 VAC
K8
J10
BRN
THERM
SWITCH
Heater
2.7kW @ 230 VAC