6. Establish A Stable Sanitizer Reading
Establish a stable sanitizer reading between 3.0-4.0 ppm chlorine or 2.0-4.0
ppm bromine. To ensure healthy water conditions, always maintain a constant
sanitizer reading within the levels recommended by the Association of Pool And
Spa Professionals/USA printed on the inside cover of this manual. If sanitizer
levels cannot be stabilized, perform the decontamination procedure steps 9-16
on page 18-19. Note: the "decontamination procedure" steps 9-16 should also
be used after the spa has been "Winterized" (section 12.7 page 31) or has been
sitting without power for an extended period.
7. Set Spa To Heat
To warm spa water to a comfortable temperature, follow
these steps:
The LED display on the control panel displays the
actual temperature of the spa water. Press either the
COOLER (
play the "set" temperature for 5 seconds. If you want the water to heat to a
different temperature, simply press COOLER (
5 seconds. The set temperature increases or decreases by one degree each
time one of these buttons is pressed.
The heater will turn off when the temperature corresponding to the thermo-
stat setting is achieved.
Important Heater Details:
The maximum water temperature setting for your spa is 104°F (40°C) and
the minimum setting is 65°F (18°C).
For North America spas connected to a 40 amp service, jets pump #1 must
be set to low speed and jets pump #2 must be turned off to operate the
heater.
For Export spas connected to a 20 amp service, jets pump #1 must be set
to low speed and jets pump #2 must be turned off to operate the heater.
Setting the thermostat at maximum will not accelerate the heating process.
This will only result in a higher ultimate temperature.
The heater operates until the water reaches the programmed "set tempera-
ture", then turns off. The heater will reactivate after the water cools to
approximately 1.5° below the set temperature.
8. Place Cover On Spa
Keeping the insulating cover in place anytime the spa is not in use will
reduce the time required for heating, thereby minimizing operating costs.
The time required for initial heat-up will vary depending on the starting
water temperature.
DANGER: Risk of injury, always check water temperature carefully
before entering spa!