MicroDock II
Users Manual
Table 8. Inserting the GasAlertMicro
Item
1
Docking module lid
2
Release tabs
3
Detector bay
4
Charge status indicator
(charging model only)
5
Connector pins
(charging model only)
6
Alligator clip
1.
Activate the detector and wait until it is in normal
operating mode.
2.
Ensure the alligator clip is closed and the ring is
resting flat on the detector to prevent disruptions
with transmission.
3.
Press the two release tabs on the docking module
and raise the lid.
4.
Insert the bottom of the detector into the detector
bay (LCD face down) and then lower the top into
place.
14
Description
5.
Lower the lid and press down until the release tabs
click.
When the detector has been inserted correctly, the
RUN LEDs on the docking module light yellow and
Unit Inserted screen displays.
The station LCD displays the following docking
module identification; the
•
type of detector that is inserted, and
•
bay and serial number of the docking module.
6.
To bypass the station identification screen, press
any C button on the station.
Inserting the GasAlertMicro 5 and
GasAlertMicro 5 PID
a
Infrared or intense ambient light (sun or halogen) may
interfere with the station/detector communication.
Caution