5-10. Connecting 240 Volt Input Power

3
6
8
L2
L1
240 VAC,
1−Phase
OM-278400 Page 20
.
A complete Parts List is available at www.HobartWelders.com
1
=GND/PE Earth Ground
7
2
4
L1
5
L2
9
1
!
Installation must meet all National
and Local Codes − have only
qualified
persons
make
installation.
!
Disconnect and lockout/tagout in-
put power before installing recep-
tacle. Follow established proced-
ures regarding the installation and
removal of lockout/tagout devices.
!
Always
connect
green
green/yellow conductor to supply
grounding terminal first, and never
to a line terminal.
See rating label on unit and check input
voltage available at site.
1
Input Power Cord
2
Disconnect Device (switch shown in
the OFF position)
3
Disconnect Device Grounding
Terminal
4
Disconnect Device Line Terminals
5
Black And White Input Conductor
(L1 And L2)
6
Green Or Green/Yellow Grounding
Conductor
Connect green or green/yellow grounding
conductor to disconnect device grounding
terminal first.
Connect input conductors L1 and L2 to
disconnect device line terminals.
7
Over-Current Protection
Select type and size of over-current
protection using Section 5-8 (fused dis-
connect switch shown).
8
Proper Receptacle
(NEMA 6-50R) (Customer Supplied)
Receptacle must comply with applicable
codes.
9
Plug (NEMA 6-50P)
.
A molded 240 volt plug is shown. Con-
nections are the same for units using
NEMA 6−5OP MVP plug (see Section
5−6.)
Connect plug to properly installed
receptacle.
Close and secure door on disconnect
device. Remove lockout/tagout device,
and place switch in the On position.
Ref. Input10 2015−04 − 279230