B-30
LIMITS
Limits allow the welder to adjust the welding procedure
only within a defined range.
Each user memory may have a different set of limits.
For example, memory 1 can be set to limit the WFS to
200 through 300 in/min, and memory 2 can be set to
limit the WFS to 275 through 310 in/min, while memo-
ry 3 may not have any WFS limits.
Parameters are always constrained by machine limits.
When memory limits are enabled, the parameter will
flash whenever an attempt is made to exceed the
memory limit value. The parameter will not flash if an
attempt is made to exceed the machine limit.
Machine limits are:
Range
Parameter
Weld mode dependent
Wire Feed
and gear box ratio
Speed
dependent
Weld mode dependent
Voltage
0.50 to 1.50
Trim
-10.0 to 10.0
Arc Control
0.0 to 2.5
Preflow
0.0 to 10.0
Start Time
Off, 50 to 150
Run-In WFS
0.0 to 10.0
Crater Time
0.00 to 0.25
Burnback Time
0.0 to 10.0
Postflow Time
Limits may be set for:
• Wire Feed Speed/Amperage
• Voltage/Trim
• Arc Control
• Preflow Time
• Run-In Speed
• Start Wire Feed Speed
• Start Voltage/Trim
Weld modes cannot be selected through the Limits
Setup menu, and must be chosen and saved to mem-
ory before entering the Limits Setup Menu.
All manuals and user guides at all-guides.com
OPERATION
Units
in/min
Volts
--
Weld mode dependent
Seconds
Seconds
in/min
Seconds
Seconds
Seconds
• Start Time
• Burnback Time
• Crater Wire Feed Speed
• Crater Voltage/Trim
• Crater Time
• Postflow Time
POWER FEED® 25M
To set limits, press the desired memory button 1-6
and hold for 5 seconds. Release the memory button
when the LED begins to blink rapidly and the MSP4
displays "Memory X Set Limits" as shown below.
Set Limits:
Press 5
seconds
MEMORY
M
PROCEDURE
A
GUN B
1
2
HOLD 2 SECONDS TO SAVE
4
5
MSP4 DISPLAY
WAVEFORM CONTROL TECHNOLOGY
Memory 1
IR PORT
Set Limits
WELD MODE
ARC CONTROL
SET
B-30
M
3
6
SETUP
START OPTIONS
END OPTIONS

Advertisement