WELD CABLE SIZE
Table A.1 located below are copper cable sizes recom-
mended for different currents and duty cycles. Lengths
stipulated are the distance from the welder to work and
back to the welder again. Cable sizes are increased for
greater lengths primarily for the purpose of minimizing
cable drop.
RECOMMENDED CABLE SIZES (RUBBER COVERED COPPER - RATED 167°F or 75°C)**
AMPERES
PERCENT
DUTY
CYCLE
200
60
200
100
225
20
225
40 & 30
250
30
250
40
250
60
250
100
300
60
325
100
350
60
400
60
400
100
500
60
** Tabled values are for operation at ambient temperatures of 104°F(40°C) and below. Applications above 104°F(40°C) may require cables
larger than recommended, or cables rated higher than 167°F(75°C).
All manuals and user guides at all-guides.com
INSTALLATION
FIGURE A.5
W W o o r r k k
Power Source
Power Source
W W ork
ork
Electrode
Electrode
Coaxial W

Coaxial Weld Cable

TABLE A.1
CABLE SIZES FOR COMBINED LENGTHS OF ELECTRODE AND WORK CABLES
0 to 50Ft.
50 to 100Ft.
(0 to15M)
(15 to 30M)
2
2
4 or 5
3
3
2
1
1
1
2/0
1/0
2/0
3/0
2/0
POWER FEED® 25M
COAXIAL WELD CABLE
Coaxial welding cables are specially designed welding
cables for pulse welding or STT™ welding. Coaxial weld
cables feature low inductance, allowing fast changes in
the weld current. Regular cables have a higher inductance
which may distort the pulse or STT™ wave shape.
Inductance becomes more severe as the weld cables
become longer.
Coaxial weld cables are recommended for all pulse and
STT™ welding, especially when the total weld cable
length (electrode cable + work cable) exceeds 50 feet
(7.6m).
A coaxial weld cable is constructed with multiple small
leads wrapped around one large lead. The large inner
lead connects to the electrode stud on the power source
and the electrode connection on the wire feeder. The
small leads combine together to form the work lead, one
end attached to the power source and the other end to the
work piece. See Figure A.5
W W o o r r k k
E E l l e e c c tr tro o d d e e
eld Cable
Electrode
Electrode
Wire Feeder
Wire Feeder
W W ork
ork
100 to 150 Ft.
(30 to 46M)
2
2
2
2
3
2
3
2
3
2
2
1
1
1
1
1
1
1
2/0
2/0
1/0
2/0
2/0
2/0
3/0
3/0
2/0
3/0
150 to 200 Ft.
200 to 250 Ft.
(46 to 61M)
(61 to 76M)
1
1/0
1
1/0
1
1/0
1
1/0
1
1/0
1
1/0
1
1/0
1
1/0
1/0
2/0
2/0
3/0
2/0
3/0
3/0
4/0
3/0
4/0
3/0
4/0