B-28
P.99
Show Test Modes
Many weld tables include special modes for
testing and servicing the welding system. Set
this parameter to YES to show all test modes.
When the power source is turned off, the Show
Test Modes parameter automatically reverts
back to "NO".
P.100
View Diagnostics
Diagnostics are only used for servicing the
Power Wave system.
Yes = Shows P.101 through P.500 in the
SETUP menu.
No = Only P.0 through P.100 are shown in the
SETUP menu.
P.101
Event Logs
Press the right MSP4 button to view the Event
Logs. Rotate the encoder to select the object
to read and then press the right MSP4 button.
Various software information will appear about
key system events. Press the left MSP4 button
to exit.
P.102
Fatal Logs
Press the right MSP4 button to view the Fatal
Logs. Rotate the encoder to select the module
to read and then press the right MSP4 button.
Various software information will appear about
critical module actions. Press the left MSP4
button to exit.
P.103
Software Version
Press the right MSP4 button to view the soft-
ware loaded into each module (p.c. board).
Rotate the encoder to select the module to
read and then press the right MSP4 button.
The panel will display the main software ver-
sion loaded into the module. Press the left
MSP4 button to exit.
P.104
Hardware Version
Press the right MSP4 button to view the hard-
ware version of each module (p.c. board).
Rotate the encoder to select the module to
read and then press the right MSP4 button.
The panel will display the main hardware ver-
sion loaded into the module. Press the left
MSP4 button to exit.
P.105
Welding Software
Press the right MSP4 button to view the weld-
ing software version inside the power source.
Press the left MSP4 button to exit.
All manuals and user guides at all-guides.com
OPERATION
POWER FEED® 25M
P.106
Ethernet IP Address
Press the right MSP4 button to view the IP
address of the Ethernet board. If no Ethernet
Board is installed, the display shows "No Enet
Found." Press the left MSP4 button to exit.
P.107
Power Source
Press the right MSP4 button to view the type of
power source connected to the control box.
Press the left MSP4 button to exit.
B-28