USER PROGRAMMING

The SXT control was designed to operate under most
conditions with minimal programming. Follow the procedure
below to set up the control for normal operation. For more in-
depth programming information, see the Master Programming
section.
Abbreviation
Parameter
DO
Day Override
RT
Regeneration Time
H
Feed Water Hardness
RC or SF
Reserve Capacity
CD
Current Day
NOTE: Some items may not be shown depending on control
configuration. The control will discard any changes
and exit User Programming Mode if a button is not
pressed for 60 seconds.
User Programming Mode Steps
1. Press the Up and Down buttons for five seconds while in
service, and the time of day is NOT set to 12:01 PM.
2. Use this display to adjust the Day Override. This option
setting is identified by "DO" in the upper left hand corner of
the screen.
Figure 4
3. Press the Extra Cycle button. Use this display to adjust the
Regeneration Time. This option setting is identified by "RT"
in the upper left hand corner of the screen.
Figure 5
Description
The control's day override
setting.
The time of the day that
the system will regenerate
(meter delayed, time clock,
and day-of-week systems)
The hardness of the inlet
water - used to calculate
system capacity for
metered systems.
The fixed reserve
capacity of the system
in gallons to maintain
before the next scheduled
regeneration. Can also
be set as a percentage of
total capacity. See Master
Programming section..
The current day of week.
4. Press the Extra Cycle button. Use this display to adjust the
Feed Water Hardness. This option setting is identified by
"H" in the upper left hand corner of the screen.
Figure 6
Range: 1-199 hardness
5. Press the Extra Cycle button. Use this display to adjust the
Fixed Reserve Capacity. This option setting is identified by
"RC" or "SF" in the upper left-hand corner of the screen.
NOTE: This setting is dependent upon Reserve Selection
setting in Master Programming. Default is RC -
Reserve Capacity (Gallons). See Master Programming
section for more information.
Figure 7
6. Press the Extra Cycle button. Use this display to set the
Current Day of the Week. This option setting is identified by
"CD" in the upper left hand corner of the screen.
Figure 8
7. Press the Extra Cycle button to end User Programming.
FLECK 5810 & 5812 SXT Upflow/Downflow • 5