MASTER PROGRAMMING MODE continued
10. Day Override (Display Code DO)
Press the Extra Cycle button. Use this display to set the Day
Override. This setting specifies the maximum number of days
between regeneration cycles. If the system is set to a timer-
type control, the day override setting determines how often
the system will regenerate. A metered system will regenerate
regardless of usage if the days since last regeneration cycle
equal the day override setting. Setting the day override value
to "OFF" disables this function. This option setting is identified
by "DO" in the upper left hand corner of the screen. Use the Up
and Down buttons to adjust the value as needed.
Figure 18
Range: Off-99 days
11. Regeneration Time
Press the Extra Cycle button. Use this display to set the
Regeneration Time. This setting specifies the time of day the
control will initiate a delayed, manually queued, or day override
regeneration. This option setting is identified by "RT" in the
upper left hand corner of the screen. Use the Up and Down
buttons to adjust the value as needed.
Figure 19
12. Regeneration Cycle Step Times
Press the Extra Cycle button. Use this display to set the
Regeneration Cycle Step Times. The different regeneration
cycles are listed in sequence based on the valve type selected
for the system, and are identified by an abbreviation in the
upper left-hand corner of the screen. The abbreviations used
are listed below.
Abbreviation
BD
BF
AD
BW
RR
SV
10 • FLECK 5810 & 5812 SXT Upflow/Downflow
Cycle Step
Brine Draw
Brine Fill
Air Draw
Backwash
Rapid Rinse
Service
If the system has been configured with the "Other" valve type,
the regeneration cycles will be identified as C1, C2, ..., C20.
Cycle steps can be programmed in any order using the Up or
Down buttons with the following selections. Up to 20 individual
cycles can be set. Time for each cycle can be set from 0 to 199
minutes. Setting a cycle step time to 0 will cause the control
to skip that step during regeneration, but keeps the following
steps available. Use the Up and Down buttons to adjust the
value as needed. Press the Extra Cycle button to accept the
current setting and move to the next parameter. Program the
last cycle step as LC which forces the valve back to the service
position.
Abbreviation
RR
BD
SR
BW
RF
SP
LC
Figure 20
Range: 0-199 minutes
13. Day of Week Settings
Press the Extra Cycle button. Use this display to set the
regeneration schedule for a system configured as Day of Week
control. The different days of the week are identified as D1,
D2, D3, D4, D5, D6, and D7 in the upper left-hand corner of the
display. Set the value to "ON" to schedule a regeneration or
"OFF" to skip regeneration for each day. Use the Up and Down
buttons to adjust the setting as needed. Press the Extra Cycle
button to accept the setting and move to the next day. Note that
the control requires at least one day to be set to "ON" If all 7
days are set to "Off", the unit will return to Day 1 until one or
more days are set to "ON".
Figure 21
Cycle Step
Rapid Rinse
Brine Draw
Slow Rinse
Backwash
Refill
Service Position
Last Cycle