Pentair FLECK 5810 SXT UPFLOW/DOWNFLOW Service Manual page 11

Hide thumbs Also See for FLECK 5810 SXT UPFLOW/DOWNFLOW:
Table of Contents

Advertisement

MASTER PROGRAMMING MODE continued
14. Current Day (Display Code CD)
Press the Extra Cycle button. Use this display to set the current
day on systems that have been configured as Day of Week
controls. This setting is identified by "CD" in the upper left-
hand corner of the screen. Use the Up and Down buttons to
select from Day 1 through Day 7.
Figure 22
15. Flow Meter Type (Display Code FM)
Press the Extra Cycle button. Use this display to set the type
of flow meter connected to the control. This option setting
is identified by "FM" in the upper left-hand corner of the
screen. Use the Up and Down buttons to select one of the eight
available settings.
Abbreviation
P0.7
t0.7
P1.0
t1.0
t1.2
P1.5
t1.5
P2.0
Gen
Figure 23
16. Meter Pulse Setting (Display Code K)
Press the Extra Cycle button. Use this display to specify the
meter pulse setting for a non-standard flow meter. This option
setting is identified by "K" in the upper left-hand corner of
the screen. Use the Up and Down buttons to enter the meter
constant in pulses per unit volume.
Figure 24
17. End of Master Programming Mode
Press the Extra Cycle button to save all settings and exit
Master Programming Mode.
Description
3/4" Paddle Wheel Meter
3/4" Turbine Meter
1" Paddle Wheel Meter
1" Turbine Meter
1.25" Turbine Meter
1.5" Paddle Wheel Meter
1.5" Turbine Meter
2" Paddle Wheel Meter
Generic or Other non-Fleck Meter
FLECK 5810 & 5812 SXT Upflow/Downflow • 11