Error Messages - B.Pro B.PROTHERM 420 KBUH Translation Of The Original Operating Instructions

Table of Contents

Advertisement

/:

Error messages

Code
HS: (H5) Heating short-
FB: (F6)
FS: (F5)
Uo
Uu
B.PROTHERM 420 KBUH/420 KBRUH/620 KBUH/620 KBRUH
Heating
active
Heating
inactive
Error
Cause
Short-circuit in the
circuit; power is
PTC heating element;
switched off
moisture may have en-
tered the PTC heating
element aluminium
housing
Sensor break
Defective temperature
sensor, resistance
curve outside toler-
ance
Sensor short-
Temperature sensor
circuit
input lines generate a
short-circuit; resist-
ance curve outside tol-
erance levels
No display
Overvoltage
>260 V
Undervoltage
<200 V
– 25 –
Measure
 Check that the
heating element
compound is leak-
tight.
 Fit new heating ele-
ment if necessary.
 Replace NTC sen-
sor.
 Replace NTC sen-
sor
 Check mains sup-
ply lines and unit
fuse on controller
electronics.
 Check mains
voltage
 Check mains
voltage

Advertisement

Table of Contents
loading

Table of Contents