Technical Data; Electrical Data - B.Pro B.PROTHERM 420 KBUH Translation Of The Original Operating Instructions

Table of Contents

Advertisement

B.PROTHERM 420 KBUH/420 KBRUH/620 KBUH/620 KBRUH
General data

Electrical data

Technical data

I
A unit subject to these operating instructions may also have differing
technical data (electrical and refrigeration-related specifications, dimen-
sions), depending on the model. The mandatory information is provided
on the rating plate or in the specific order documents and/or on drawings.
Dimensions, weight and capacities
Model
Dimensions in mm
(Length x Width x
Height)
420 KBUH/
692 x 445 x 470
420 KBRUH
620 KBUH/
692 x 440 x 690
620 KBRUH
Maximum load
Model
420 KBUH/ 420 KBRUH
620 KBUH/ 620 KBRUH
Temperature in unit interior
B.PROTHERM 420 KBUH/620 KBUH
Approx. +90 °C
B.PROTHERM 420 KBRUH/620 KBRUH
Can be set between approx. +40 °C and +85 °C, in 1-degree increments
About +90 °C in "Full Power" mode (FP)
Thermal class
A in accordance with DIN EN 12571
Connected loads
Voltage:
Output:
The pickup power of the unit while cold is 800 Watts.
Protection type
IP X4 (do not use steam jet units, high-pressure cleaners or similar cleaning
devices).
– 32 –
Ap-
Capacity (GN 1/1 con-
prox.
tainers)
empty
weight
in kg
16
Two containers with a
depth of 150 mm (exam-
ple)
19.5
Two containers with a
depth of 200 mm (exam-
ple)
Maximum load in kg
50
70
220 to 240 V AC, 50 to 60 Hz
(purely sinusoidal AC)
200 Watt