11 Bypass actuator version
Pneumatically operated, normally closed, dia-
phragm size 8,
Pneumatically operated, normally open, diaphragm
size 8,
Manually operated, with seal adjuster, diaphragm
size 8,
12 Special specification
Ra ≤ 0.25 µm (10 µin.) for media wetted surfaces
*),
in accordance with DIN 11866 HE5,
electropolished internal/external,
*) for inner pipe diameters < 6 mm, in the spigot Ra
≤ 0.38 µm
Ra ≤ 0.25 µm (10 µin.) for media wetted surfaces
*),
in accordance with DIN 11866 H5,
mechanically polished internal,
*) for inner pipe diameters < 6 mm, in the spigot Ra
≤ 0.38 µm
Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces,
in accordance with DIN 11866 H4,
mechanically polished internal
Ra ≤ 0.4 µm (15 µin.) for media wetted surfaces,
in accordance with DIN 11866 HE4,
electropolished internal/external
Ra max. 0.51 µm (20 µin.) for media wetted sur-
faces,
in accordance with ASME BPE SF1,
mechanically polished internal
Ra max. 0.38 µm (15 µin.) for media wetted sur-
faces,
in accordance with ASME BPE SF4,
electropolished internal/external
Ra max. 0.51 µm (20 µin.) for media wetted sur-
faces,
in accordance with ASME BPE SF5,
electropolished internal/external
13 Special version
Special version for 3A
14 CONEXO
Without
Integrated RFID chip for electronic identification
and traceability