3. Clean the inside of the cup with a light oil.
4. Clean the area around the fuel filter/water separator
head.
5. Reattach the cup to the filter head assembly.
6. Place the fuel valve lever in the OPEN position.
7. Air bleed the fuel system before starting the engine.
DRAINING THE CONTAINMENT TANK
NOTICE
When the "Fuel Leak Detect Lamp" turns on it indicates
that the fluid level in the environmental tank has
reached the warning level and that it is now time to
drain the environmental tank.
1. This generator is equipped with an environmental
containment tank. Inspect this tank regularly.
2. If the tank becomes full with fluids, remove the drain
bolt (Figure 61), then allow the fluids to drain into a
suitable container.
4 0
Figure 61. Draining Containment Tank
DCA40SSKU4F2 60 HZ GENERATOR • OPERATION MANUAL — REV. #2 (08/30/22) — PAGE 41
CONTAINMENT
DRAIN BOLT
CLEANING INSIDE THE FUEL TANK
If necessary, drain the fuel inside the fuel tank completely.
Using a spray washer (Figure 62) wash out any deposits
or debris that have accumulated inside the fuel tank.
Figure 62. Fuel Tank Cleaning
FUEL TANK INSPECTION
In addition to cleaning the fuel tank, the following
components should be inspected for wear:
„ Rubber Suspension — Look for signs of wear or
deformity due to contact with oil. Replace the rubber
suspension if necessary.
„ Fuel Hoses — Inspect nylon and rubber hoses for signs
of wear, deterioration or hardening.
„ Fuel Tank Lining — Inspect the fuel tank lining for signs
of excessive amounts of oil or other foreign matter.