Related Parameters

The following parameters set the drive for operation with the option. Set parameters as
needed. Parameter setting methods can be found in the drive Quick Start Guide or Technical
Manual.
No.
Name
(Addr. Hex)
A1-02
Control Method
(102)
Selection
F1-01
PG 1 Pulses per
(380)
Revolution
<2>
PG Feedback
F1-02
Loss Operation
(381)
Selection
PG Overspeed
F1-03
Operation
(382)
Selection
PG Deviation
F1-04
Operation
(383)
Selection
F1-05
PG 1 Rotation
(384)
YASKAWA ELECTRIC TOBP C730600 52D 1000-Series Option PG-E3 Installation Manual
Table 6
Related Parameters
Description
0: V/f Control
1: V/f Control with PG
2: Open Loop Vector Control
3: Closed Loop Vector Control
5: Open Loop Vector Control for PM
6: Advanced Open Loop Vector Control for PM
7: Closed Loop Vector Control for PM
Note: Set to 7 when using PG-E3.
Sets the signal periods per revolution to be read from
the pulse generator.
Sets the stopping method after PG disconnect (PGo).
0: Ramp to stop (decelerates at time set to C1-02)
1: Coast to stop
2: Fast Stop (decelerates at the time set to C1-09)
3: Continue running
4: No alarm display
NOTICE: Due to potential damage to the motor and
machinery, only use settings 3 and 4 under special
circumstances.
Sets the stopping method after detecting overspeed.
0: Ramp to stop (decelerates at time set to C1-02)
1: Coast to stop
2: Fast Stop (decelerates at the time set to C1-09)
3: Continue running
NOTICE: Due to potential damage to the motor and
machinery, do not use the "Continue running" setting
except under special circumstances.
0: Ramp to stop (decelerates at time set to C1-02)
1: Coast to stop
2: Fast Stop (decelerates at the time set to C1-09)
3: Continue running
NOTICE: Due to potential damage to the motor and
machinery, do not use the "Continue running" setting
except under special circumstances.
0: Forward = A pulse leads
1: Forward = B pulse leads
6 Related Parameters
Control
Mode
Default:
All Modes
Range:
Default:
CLV
Min:
CLV/PM
Max:
CLV
Default: 1
CLV/PM
Range:
CLV
Default: 1
CLV/PM
Range: 0 to 3
CLV
Default:
CLV/PM
Range: 0 to 3
CLV
Default:
CLV/PM
Range: 0, 1
Values
<1>
<1>
<1>
<1>
<1>
<1>
<1>
<1>
27

Advertisement

loading

This manual is also suitable for:

L1000aPg-e3