Airflow And Temperature; Output Cable Harness; Table 6. Thermal Environmental Requirements - Intel E80367-001 Product Specification

Server system
Table of Contents

Advertisement

®
Intel
Server System SC5650BCDP TPS
3.1.2

Airflow and Temperature

The power supply incorporates one 80-mm fan for self and system cooling. The fan provides no
less than 14 CFM of airflow through the power supply when installed in the system. The cooling
air enters the power module from the non-AC side. The power supply operates within all
specified limits over the T
ITEM
T
Operating temperature range.
op
T
Non-operating temperature range.
non-op
Altitude
Maximum operating altitude
The power supply meets UL enclosure requirements for temperature rise limits. All sides of the
power supply, with the exception of the air exhaust side, are classified as "Handle, knobs, grips,
etc. held for short periods of time only."
3.1.3

Output Cable Harness

Listed or recognized component appliance wiring material (AVLV2), CN, rated min 105
300Vdc is used for all output wiring.
Revision 1.0
temperature range.
op

Table 6. Thermal Environmental Requirements

DESCRIPTION
Intel order number: E80367-001
MIN
Specification
0
50
-40
70
1500
Power Sub-System
UNITS
°C
°C
m
C,
°
13