(4) Detaching and refitting the high voltage PWB

Procedure
1. Remove the developing unit (See page 1-5-
11).
2. Remove the drum unit (See page 1-5-12).
3. Remove the cassette (See page 1-5-6).
4. Remove the outer covers (See page 1-5-3).
5. Remove the power source PWB (See page
1-5-22).
6. Turn the printer with the bottom side up.
7. Simplex model: Proceed to the step 12.
Duplex model: Proceed to the step 8.
8. Remove the stop ring.
9. Remove the DU holder.
10. Pull out the DU bush.
11. Remove the DU cover assembly.
All manuals and user guides at all-guides.com
DU cover assembly
Stop ring
DU holder
Figure 1-5-34
DU bush
Figure 1-5-35
2H5/2HS
1-5-25