Kyocera FS-1100 Service Manual page 75

Hide thumbs Also See for FS-1100:
Table of Contents

Advertisement

6. Remove four screws and then remove the
power source plate from the power source
PWB.
7. Check or replace the power source PWB
and refit all the removed parts.
Caution: The power source film must be
installed in the specified position.
All manuals and user guides at all-guides.com
Screws
Power source PWB
Power source plate
Figure 1-5-32
2H5/2HS
Screws
Power source film
1-5-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fs-1300d

Table of Contents