(2) Detaching and refitting the power source PWB

Procedure
1. Remove the top cover (See page 1-5-3).
2. Remove the left cover (See page 1-5-4).
3. Remove four connectors.
4. Remove four P tight screws, two screws and
ground terminal.
5. Remove the power source PWB assembly
from the high voltage PWB's connector.
1-5-22
All manuals and user guides at all-guides.com
Connector
Ground
terminal
Screws
P tight screws
Connector
Connector
Figure 1-5-30
High voltage PWB
Connector
(YC103)
Power source PWB
assembly
P tight screws
Figure 1-5-31
Connector
(YC104)
Connector
(YC201)