18. Check or replace the high voltage PWB and
refit all the removed parts.
When refitting the high voltage PWB, be
careful about following points.
- Position the ground plate so that it is atop
the high voltage PWB.
- Each interface is firmly in contact with each
spring.
- The bias contact pin must be installed in
the specified position.
- The cassette pin must be inserted in the
cassette pin holder.
1-5-28
All manuals and user guides at all-guides.com
High voltage PWB
Spring
(Transfer)
Cassette pin holder
OK
Ground plate
Spring
(separation)
Spring
(Main charger)
High voltage PWB
Cassette pin
Figure 1-5-39
NG
High voltage PWB
Spring
(Developing)
Bias
contact pin

Advertisement